Abstract

Thermal accumulation in micro droplet deposition manufacturing (MDDM) has a significant influence on geometric profile and microstructure of the fabricated metal micro-parts. In this paper, thermal behavior of a new aluminum droplet on the deposit surface was investigated using one-dimensional heat transfer model. Then several thin-walled aluminum cubic pipes were fabricated by MDDM to verify the numerical analysis result. The result shows that the thermal accumulation would increase gradually with the increase of the deposit height. It associated with thermal input and output on the top surface of the deposit, which could be controlled or eliminated by optimizing processing parameters such as deposition frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.