Abstract

Objective To explore the clinical application of preoperative 3D printing design combined with minimally invasive percutaneous plate internal fixation (MIPPO) in the treatment of middle and lower tibiofibular fractures. Methods Retrospective analysis of clinical data of 110 patients with fractures of the middle and lower tibia in the Department of Orthopaedics, Yizheng People's Hospital from January 2012 to June 2017. Preoperative 3D printing design combined with minimally invasive percutaneous plate internal fixation technology (3D printing group) was performed in 48 patients, including 28 males and 20 females, 17 on the left and 31on the right, aged from 19 to 68 (42.5±5.7) years.According to AO/OTA classification, there were 11 patients of type A, 19 patients of type B, and 18 patients of type C. Open reduction and internal fixation (ORIF group) was used in 62 patients, including 34 males and 28 females; 25 on the left and 37 on the right. aged from 21 to 72 (44.7±7.5) years. According to AO/OTA classification, there were 16 patients of type A, 22 patients of type B, and 24 patients of type C. The operation data such as incision length, the amount of bleeding, the X-ray exposure times, the hospitalization time, the fracture healing time, excellent and good rate of ankle joint function and incidence of complications were recorded and analyzed. Results All patients were followed up for 12.0 to 18.0 (13.6±2.5) months. The length of the incision (the cumulative length of the tibia) in the 3D print group and the ORIF group were (7.57±1.63) cm and (12.7±2.73) cm.The amount of bleeding were(45.7±10.5) mL and (120.3±17.9) mL, respectively.The hospitalization time of the two groups were (10.3±3.17) d and (13.9±3.43) d, respectively. The X-ray exposure times were (3.07±2.13) times and (1.46±1.85) times, respectively. The fracture healing time were(4.2±2.65) months and (5.9±2.32) months, respectively. The functional scores of the ankle joint Johner-Wruhs in the 3D print group and the ORIF group were excellent in 27 patients, good in 17 patients, fair in 4 patients, and excellent in 25 patients, good in 24 patients, fair in 11 patients, and poor in 2 patients, the difference was statistically significant (Z=2.555, P 0.05). Conclusions Preoperative 3D printing design combined with minimally invasive percutaneous plate internal fixation for the treatment of the middle and lower tibiofibular fractures can fully evaluated fracture before surgery.It has minimal traumatic features such as less trauma and less bleeding, and can promote fracture healing and improve ankle function. Key words: Tibial fractures; Fracture fixation, internal; 3D printing technology; Surgery, minimally invasive

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.