Abstract

Purpose/Background: Percutaneous left ventricular assist devices (pVADs) require a continuous purge solution containing heparin to prevent pump thrombosis and device failure. Data regarding alternative options in patients who have suspected heparin-induced thrombocytopenia (HIT) are limited. Methods: In this report, we describe a 68-year-old white man with cardiogenic shock with an Impella CP device managed with a low concentration argatroban-based purge solution secondary to a suspected diagnosis of HIT. Results: The purge solution was initiated as argatroban in dextrose 10% at a concentration of 0.12 mg/mL and was subsequently decreased twice to 0.06 and 0.015 mg/mL based on the patient's clinical course. Conclusions: This case report describes the safe and effective use of argatroban purge solution necessary for anticoagulation although further studies are needed to confirm these findings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.