Abstract

Test results for leakage and rotordynamic coefficients are presented for a honeycomb-stator/smooth-rotor annular seal for eccentricity ratios out to 0.5 using air as the test fluid. Tests were conducted at supply pressures up to 70 bars and running speeds up to 20200 rpm. The seal has a diameter of 115 mm, a cell width of 0.79 mm, and a cell depth of 3.10 mm. Tests were conducted for the back-pressure ratios of 0.35, and 0.5. Comparisons are made to predictions from an analysis due to San Andres. The test results show a minimal sensitivity of either leakage or rotordynamic coefficients to changes in the eccentricity ratio. The predictions generally agree well with measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.