Abstract
This paper proposes novel mixed-mode S -parameters, which are dubbed as “extended mixed-mode S -parameters.” The extended mixed-mode S -parameters were applied to three-conductor transmission lines, resulting in the independent differential and common modes using the current division factor of three-conductor transmission lines. By contrast to the conventional mixed-mode S -parameters, there are no cross-mode S -parameters in the extended mixed-mode S -parameters, even in the asymmetrical conductor transmission lines. In addition, two new mode conversion matrices, which contain the current division factor, are also proposed to convert the extended mixed-mode S -parameters to the standard S -parameters. The validity of the proposed extended mixed-mode S -parameters and the mode conversion method were confirmed by comparing the S -parameters from the theory, EM-simulation, and experiment as well.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Electromagnetic Compatibility
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.