Abstract
Using two approximations, the original set of basic equations of Part I applying to a Star connected stator winding is converted into explicit expressions for the average field current If, the commutation angles β and μ, the instantaneous values of all rotor currents and the DC output voltage. The particular characteristics of a Delta connected stator winding are discussed and its equations derived. All expressions are shown both in absolute as well as in per-unit values and can also be used as the initial approximation for the iterative process required to solve the basic set of exact equations of Part I. A numerical example demonstrates the capabilities of the equations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.