Abstract

Experimental determinations of the arterial compliance C are discussed, based on a simplified formula involving the systolic and diastolic pressures, the period of diastole and the peripheral resistance. The resistance is expressed in terms of the cardiac output and the mean arterial pressure during diastole, which is derived from an assumed exponential pressure-time curve and leads to a still simpler expression for C. The cardiac output is obtained by a rebreathing method that yields arterial and venous P co 2, the latter from extrapolation based on a linear difference equation. The experimental standard error of the compliance in terms of those of the various physiological parameters is considered. Numerical examples are given for a healthy man.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.