Abstract

The theoretical maximum ideal pumping efficiency of a water jet pump is 50% at a flow ratio of unity. Pump performance can be predicted theoretically. With a pump designed with theoretically obtained optimum dimensions, a maximum efficiency of 39.8% was achieved. Efficiencies on the order of 42% could be obtained by selecting proper materials to reduce friction losses to a minimum. If a jet pump with fixed nozzle is constructed for maximum efficiency, the area ratio should be between 0.33 to 0.543; for adjustable nozzle pumps, the area ratio should be about 0.205, and the pump should be operated at a nozzle distance of one to two nozzle diameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.