Abstract
This research explores the heat transfer rate for micropolar fluid in a channel flow. In spite of formal Fourier’s law, the Cattaneo–Christov heat flux design is implemented in energy system. Using appropriate dimensionless parameters, the guiding coupled partial differential equations that represent the fluid flow are modified into ordinary differential equations. By executing Runge–Kutta integration procedure and the shooting method, the numerical results are achieved. The impacts of thermal relaxation time and bio-convection flow of micropolar fluid are examined in this assessment. Graphical analyses are used to assess the effects of physical factors for the momentum, micro-rotation, concentration, density of micro-organisms and temperature gradient. The skin friction values, motile density number, heat and mass transfer rate are the fascinating physical quantities whose numerical data are computed and validated against different parametric values. The variational iteration method (VIM) and Adomian decomposition method are the analytical modules which have been incorporated here for solving the nonlinear systems for showing better approximity. It is found from the study that larger the thermal relaxation time values, the more likely they are to increase heat transfer, hence lowering the fluid temperature. Moreover, both Fourier and Cattaneo–Christov heat conduction module exhibit qualitatively similar influence on embedded parameters also the temperature profile diminishes for larger values of [Formula: see text]. The culminations evidently disclose that the bio-convection Peclet number and the motile microbes parameter enhance the density of motile micro-organisms. From a computational perspective, the VIM is more effective, practical and ease of use. The numerical and analytical results are compared well with the existing articles. The optimum parameter level for maximum heat transfer is considered to be [Formula: see text]. Taguchi approach was successfully used to determine the optimum design parameters for maximum heat transfer is 1.724012 for the parameters A-5:B-5:C-0.5:D-0.5:E-0.7.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.