Abstract

Theoretical current/voltage curves for reversible and simple irreversible electrode processes are calculated for a vertical plate electrode under isothermal and non-isothermal free convection. The role played by overvoltage in velocity and concentration distribution functions is shown. The influence of the electrode height on local cd is discussed in terms of the magnitude of the exchange cd of the electrochemical reaction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.