Abstract

The degradation of concrete structures is always accompanied by the formation of cracks. Crack monitoring is hence useful in assessing the “health condition” of the structure. In our previous investigation on an optical-fiber crack sensor, we have successfully demonstrated the possibility of crack detection and monitoring without requiring prior knowledge of crack locations. Also, a single fiber can be employed to monitor a number of cracks. In practical applications, the signal loss versus crack opening relationship of the sensor needs to be properly “designed” to satisfy performance requirements on sensitivity to small cracks and/or the total number of detectable cracks (which is limited by the maximum loss at each crack). In this paper, a theoretical model for the signal loss versus crack opening relationship is developed through a combination of mechanical and optical analyses. Using concrete beams with embedded sensors, crack monitoring experiments are conducted. Test results are found to be in reaso...