Abstract

This study presents the results of the theoretical model 10 predict the centrifugal pump performance when its impeller is equipped with splitters. The proposed methodology accounts for the constructional differences of the pump equipped with splitter blades as compared with the conventional pump. For flow through axial blade rings, there is a distinct influence of the solidity on the outflow angle from the blades. This analogy is used for the derivation of a slip factor for impellers with splitters. A loss analysis procedure has been presented to predict the performance of centrifugal pumps. The result is compared with available experimental results. The predicted values of head over the operating range of flow rate of the pump have been found to be in reasonable agreement with the measurements.

Highlights

Read more

Summary

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.