Abstract
The radiation dose of workers in underground uranium mines mainly comes from radon and radon progeny. To ensure a healthy and safe work environment, it is necessary and urgent to optimize the design of ventilation systems. As such, based on the simplified radon diffusion-advection migration model of the rocks, this paper proposes 1) two methods for determining the radon exhalation rate modified by pressure drop, 2) three methods for calculating radon activity concentration of single-branch, and 3) the novel adjustment algorithm and solving procedures for calculating and adjusting the radon activity concentration in ventilation networks by modifying the radon exhalation rate, demonstrated on a specific ventilation network in a simulated underground uranium mine with calculation and analysis via MATLAB. The results show that 1) the radon exhalation rate of different branches can be modified by their pressure drop, and 2) the proposed method can be used to reveal the influences of different ventilation methods and fan pressures on the radon activity concentration in the ventilation network and the radon release rate to the atmosphere.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.