Abstract

The Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) is planning to demonstrate the performance benefits of using boil-off to reduce the heat load on various upper stage structural members by using the boil-off vapor to intercept some of the heat load on the structures. A first order simplified analytical model was constructed in order to understand sensitivity of various parameters to performance as well as to understand the theoretical maximum performance of the vapor cooling of a thin-walled cylindrical structure. Constant fluid properties and a temperature dependent thermal conductivity of the structure material were assumed. The model showed that vapor cooling of an aluminum cylindrical structure with hydrogen can reduce the heat load along the cylinder by as much as 70%. Also, cooling a portion of the cylinder is quite effective in comparison with cooling it entirely.