Abstract
In this paper we evaluate the effect of the interrogation oscillator frequency noise on the stability of a pulsed atomic frequency standard such as an atomic fountain or ion trap frequency standard. The atomic response to a phase perturbation in Ramsey and multi-Rabi interrogation schemes has been calculated using the density matrix formalism. The results of these calculations are used to obtain a simple model for the limitation of the frequency standard stability. An experimental evaluation of this effect has been performed by using the Cs atomic fountain frequency standard. Possible means to reduce this effect are considered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.