Abstract
An innovative retrofit scheme is proposed for the strengthening of old brick masonry buildings: the floor area is increased using newly added and isolated upper stories, and the lower brick masonry part is strengthened using precast concrete wall panels. To investigate the seismic performance of the innovative proposed strengthening scheme, a theoretical analysis and shaking-table tests were conducted, and the proposed scheme is compared with two conventional retrofitting schemes. The results of linear and nonlinear analyses of the three strengthening schemes indicated that all three schemes can mitigate seismic damage to old brick masonry buildings. The shaking-table tests confirmed that the proposed scheme is more effective than the two conventional schemes. Additionally, the seismic performance of the proposed strengthening scheme with post-test damage is investigated via a theoretical analysis and shaking-table tests. The results revealed that the stiffness degradation of the substructure can negatively affect the adding-story isolation system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.