Abstract

Using the previously developed cell model of a charged membrane and the principles of linear thermodynamics of irreversible processes (the Onsager approach), exact and approximate (in the case of an ideally selective membrane) analytical formulae for calculating the osmotic and electroosmotic permeability of the membrane in aqueous solutions of 1:1 electrolyte at constant electric current density and concentration gradient were suggested. The formulae have been successfully verified by our own experimental data for the extrusion cation-exchange membrane MF-4SC p.29 in NaCl solution up to concentrations of 3 M. The contribution of electroosmotic and osmotic water fluxes to the total water transport through the mentioned individual perfluorinated ion-exchange membrane under conditions close to the process of electrodialysis concentrating was experimentally estimated. The cases of co- and counter-directed osmotic and electroosmotic water fluxes are studied. A good correspondence between theoretical and experimental results was obtained, which made it possible to determine the physicochemical parameters of the electromembrane system (the diffusion coefficients of individual ions and the coefficient of equilibrium distribution of electrolyte molecules in the membrane matrix, the characteristic exchange capacity of the cell model). The achieved results make it possible to fully characterize existing and promising types of ion-exchange membranes based on the developed cell model of a charged membrane.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call