Abstract
The paper describes a general method for analysis of time courses of transmembrane voltage induced by time-varying electric fields. Using this method, a response to time-varying fields can be studied. We apply it to different field shapes used for electroporation: rectangular pulses and trains pulses. Using the described method, the course of induced transmembrane voltage is investigated for each selected pulse shape. All the studies are performed at different pulse durations, For all the pulse shapes investigated, this slows down the process of transmembrane voltage inducement. Thus, longer pulses have to be used to attain the desired voltage amplitude, as the influence of the fast, shortlived phenomena on the induced voltage is diminished.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.