Abstract
In order to apply the ground source heat pump in the drying industry, a set of open-circuit ground source heat pump drying system was designed for theoretical analysis and compared with the closed air source heat pump drying system, The results are shown below: When the drying temperature (air temperature required for drying) is 40°C-60°C, the system performance coefficient( COP) of the drying system is 3.2-5.2. Dehumidification per unit energy consumption( SMER) is affected by the external ambient temperature. The highest and lowest SMER corresponding to the ambient temperature of 20°C are 4.4 and 1.4, and the highest and lowest SMER corresponding to the ambient temperature of -10°C are 2.6 and 1.1. When the ambient temperature is high and the drying temperature of drying materials is low (less than 50°C or so), the open-circuit ground source heat pump drying system has a slight advantage over the closed air source heat pump drying system, and SMER is higher.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.