Abstract
The correction rate (CR) and fulcrum bending correction index (FBCI) based on the fulcrum bending radiograph (FBR) were parameters introduced to measure the curve correcting ability; however, such parameters do not account for contributions by various, potential extraneous "X-Factors" (e.g. surgical technique, type and power of the instrumentation, anesthetic technique, etc.) involved in curve correction. As such, the purpose of the following study was to propose the concept of the "X-Factor Index" (XFI) as a new parameter for the assessment of the correcting ability of adolescent idiopathic scoliosis (AIS). A historical cohort radiographic analysis of the FBR in the setting of hook systems in AIS patients (Luk et al. in Spine 23:2303-2307, 1998) was performed to illustrate the concept of XFI. Thirty-five patients with AIS of the thoracic spine undergoing surgical correction were involved in the analysis. Plain posteroanterior (PA) plain radiographs were utilized and Cobb angles were obtained for each patient. Pre- and postoperative PA angles on standing radiograph and preoperative fulcrum bending angles were obtained for each patient. The fulcrum flexibility, curve CR, and FBCI were determined for all patients. The difference between the preoperative fulcrum bending angle and postoperative PA angle was defined as Angle(XF), which accounted for the correction contributed by "X-Factors". The XFI, designed to measure the curve correcting ability, was calculated by dividing Angle(XF) by the fulcrum flexibility. The XFI was compared with the curve CR and FBCI by re-evaluating the original data in the original paper (Luk et al. in Spine 23:2303-2307, 1998). The mean standing PA and FBR alignments of the main thoracic curve were 58.3° and 24.5°, respectively. The mean fulcrum flexibility was 58.8%. The mean postoperative standing PA alignment was 24.7°. The mean curve CR was 58.0% and the mean FBCI was 101.1%. The mean XFI was noted as 1.03%. The CR was significantly positively correlated to curve flexibility (r=0.66; p<0.01).The FBCI (r=-0.47; p=0.005) and the XFI (r=-0.45; p=0.007) were significantly negatively correlated to curve flexibility. The CR was not correlated to Angle(XF) (r=0.29; p=0.089).The FBCI (r=0.97; p<0.01) and the XFI (r=0.961; p<0.01) were significantly positively correlated to Angle(XF). Variation in XFI was noted in some cases originally presenting with same FBCI values. The XFI attempts to quantify the curve correcting ability as contributed by "X-Factors" in the treatment of thoracic AIS. This index may be a valued added parameter to accompany the FBCI for comparing curve correction ability among different series of patients, instrumentation, and surgeons. It is recommended that the XFI should be used to document curve correction, compare between different techniques, and used to improve curve correction for the patient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.