Abstract

The automatic alignment system of the Virgo interferometer differs substantially from those used in similar experiments, since it uses a variant of the Anderson technique. This implies a completely different control topology with respect to other detectors, and the main feature is a strong coupling of different degrees of freedom in the optical signals. It also provides two extra output ports in which differential wave-front sensors can be placed, namely the light transmitted by the Fabry–Perot arm cavities. We report on the first experimental demonstration of this technique on a large scale recycled interferometer, and on the present status of the automatic alignment system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.