Abstract

A Vibrational Unconfined Compression Tester has been developed which superimposes applied vibration upon axial compression for a cylindrical sample of cohesive material. The VUCT has been applied to systems of wet sands. During applied vibration, the material retreated into elastic space within each vibration cycle. The top cap stress/axial strain curve progressed through a series of hysteresis loops. The instantaneous values of peak axial stress, Pi, and averaged values, Pave, have been compared with peak stresses for control tests with no applied vibration, Pnv. Pave always gave lower values than Pi, due to the cyclic nature of the system. However, in some tests Pi was not significantly different from Pnv. Thus, Pave is not an appropriate parameter for determination of the effects of vibration upon material strength. In some cases, vibration caused a genuine reduction in material strength as measured by peak stress. This depended upon applied vibration and material properties. The maximum reduction in strength did not correspond to resonance frequency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.