Abstract
The velocity of second soundu 2 in dilute solutions of3He in4He has been measured by a pulse, time-of-flight technique using a new type of mechanical transducer. Tables of measured values ofu 2 as a function of temperature between 0.03 and 0.6° K are presented for3He concentrations in the range 0.14–6.3% at the saturated vapor pressure and under hydrostatic pressures of 10 and 20 atm. Estimates of the upper limit of the intrinsic attenuation of second sound have also been made and these are consistent with theory provided that the experimental values of the phonon thermal conductivity lifetime are used in place of the values calculated by Baym and Ebner.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.