Abstract

This study examines the sensitivity of serial human chorionic gonadotropin determinations in the detection of ectopic pregnancy for patients who present with human chorionic gonadotropin titers <6500 mlU/ml. A log human chorionic gonadotropin time curve was used to calculate the slope of change. A slope below 0.11 (85% confidence limit for intrauterine gestations) is used as the cutoff value. Of 50 patients with serial titers at sampling intervals of 2 to 5 days, 26 (49%) had falling values and 22 had subnormal slopes. Only five had initially normal slopes and two of these patients eventually had falling titers. The sensitivity of an abnormal slope (below 0.11) in the detection of ectopic pregnancy was 90%. A 12.5% false positive rate was found in a group of 24 intrauterine pregnancies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.