Abstract

Biogas slurry is an environmental pollution source if it is discharged without proper treatment. In this work, a membrane system is designed to concentrate, and hence to recover the nutrient in the biogas slurry. The effects of pre-treatment technology, pH, temperature, operating pressure and module types of the reverse osmosis unit were studied via analyzing the chemical oxygen demand (COD), ammonia nitrogen, total nitrogen, conductivity in the permeate and retentate, and the volume concentration ratio. A dual stage reverse osmosis (RO) process is also applied to further enhance the performance, the concentration ratio reaches above 5 within 80 mins of operation, while the nutrient recovery and water recovery rates are 98% and 92.52%, respectively. The COD and ammonia nitrogen rejection rates are 99.41% and 99.11%, respectively; the quality of the permeate is in accordance with the national standard for water discharging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.