Abstract

ABSTRACTThe current study aimed to assess the validity and test–retest reliability of a linear position transducer when compared to a force plate through a counter-movement jump in female participants. Twenty-seven female recreational athletes (19 ± 2 years) performed three counter-movement jumps simultaneously using the linear position transducer and force plate for validity. In addition, 11 elite female athletes (23 ± 6 years) performed 3 counter-movement jumps with the linear position transducer on three separate days for test–retest reliability. Pearson correlations for jump height between the devices were at a high level (r = .90), with the linear position transducer overestimating jump height by 7.0 ± 2.8 cm. The reliability measured by the linear position transducer resulted in a mean intraclass correlation of .70 for jump height, .90 for peak velocity, and .91 for mean velocity. The linear position transducer was reliable for measuring counter-movement jumps in elite female athletes; however, caution should be taken for one-off jump measures as it may over-estimate jump height.