Abstract

The ability of a co-heating test to accurately identify a dwelling's envelope heat-loss coefficient has been explored using dynamic thermal simulation techniques, against a number of fabric specifications ranging from 1990 UK regulation levels through to modern Passivhaus requirements.Simple analysis methods can underestimate the heat-loss coefficient, by up to 50% for the highest performance standards considered. Using the best test and analysis methods found the envelope heat loss coefficient could be determined for current stock to better than 10% accuracy in a three week test duration. However that accuracy could not be reliably achieved in a shorter period, nor could it be achieved with a dwelling specification representing emerging standards of insulation, unless longer test periods were used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.