Abstract

ObjectivesAs a new pelvic fixation technique, the dual S2AI screws fixation technique could provide highly stable distal strength, and have wide clinical prospect in the correction of severe kyphoscoliosis. However, the ideal trajectory parameters, indications and clinical outcomes of this technique have not been reported so far. This study aimed to determine the anatomical parameters of dual S2AI screws in the normal Chinese adult population, investigating the indications of this technique and evaluating the feasibility and clinical outcomes.MethodsFifteen males and 15 females with normal pelvis underwent a pelvic CT scan to determine ideal dual S2AI screws trajectories. Sagittal angle (SA), transverse angle (TA), maximal length (ML), sacral length, and skin distance were measured. Subsequently, we retrospectively reviewed the data of 16 patients (seven males and nine females) who underwent dual S2AI screw fixation and 23 patients who underwent single S2AI screw fixation between January 2014 and December 2019. Preoperative, postoperative, and latest follow‐up measurements of Cobb angle, coronal balance (CB), spinal pelvic obliquity (SPO), and regional kyphosis (RK) were obtained. The mean follow‐up time was 16.7 ± 7.1 months (range: 12–30 months). Independent t‐test was used to determine the difference in the analysis of the trajectories. The paired sample non‐parametric Wilcoxon test was performed to assess the changes in radiographic parameters between different time points and different groups.ResultsFor both male and females, the proximal S2AI screws had significantly higher TA and ML, but a lower SA than distal screws. Females showed significantly more caudal (SA: 25.03° ± 2.32° vs. 29.82° ± 2.47°, t = 7.742, P < 0.001) trajectories of distal screw. Additionally, ML in the females were significantly shorter than that in males (106.81 mm ± 6.79 mm vs. 101.63 mm ± 6.55 mm, t = 3.007, P = 0.003, 124.41 mm ± 7.57 mm vs. 116.23 mm ± 7.03 mm, t = 4.337, P < 0.001). Eight had unilateral and eight had bilateral dual S2AI screw placement. Respectively, both the single S2AI and dual S2AI groups showed significant postoperative improvement of Cobb angle, RK angle and SPO angle. In patients with dual S2AI screws fixation, two patients found that screws loosening occurred in one of dual screws at 1‐year follow‐up, and in patients with single S2AI screws fixation, six patients found screw loosing as well as two patients found screw breakage at 1‐year follow‐up. None of all patients had any prominent loss of correction.ConclusionThe ideal trajectory of dual S2AI screw could be well established. The dual S2AI screw fixation technique is feasible in patients with severe kyphoscoliosis, and provides satisfactory correction of deformity with few postoperative complications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.