Abstract
We aimed to assess the potential utility of myometrial and cervical elasticity measurement in the diagnosis of ectopic pregnancy (EP), which could facilitate the diagnosis process. Myometrial and cervical elasticity values were measured in women with EP, women with early intrauterine pregnancy (IP) and non-pregnant women. Transabdominal point shear wave elastography (pSWE) was used for elasticity measurements. A reliability study was performed in 20 patients of the non-pregnant group. Cervical pSWE showed poor reliability and high measurement failure rate; thus, we excluded cervical elasticity assessment from the study. In this study, 32 women with EP, 28 women with early IP and 38 non-pregnant women were enrolled for myometrial elasticity assessment by pSWE. Myometrial elasticity values were statistically significantly lower in EP (8.31 kPa [5.1–27]) and early IP (8.83 kPa [4.5–46.2]) groups than in non-pregnant women (14.85 kPa [5.1–28]) (p = 0.003). However, myometrial pSWE results were not significantly different between EP and early IP groups. In light of this data, quantitative assessment of the uterus elasticity using pSWE does not seem to be an adequate diagnostic method for EP.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.