Abstract

A discussion is given of the method proposed by L a w s o n and L o n g to use the noise across a resistance as a measure of its absolute temperature. The statistical fluctuations in the measured noise are calculated, taking into account the bandwidth of the amplifier. This calculation shows that is not necessary to use a first tube with lowered voltages on plate, screengrid and heater and it shows that a quartz crystal is essentially worse than a pure resistance or a L—C circuit as a thermal noise generator for thermometrical purposes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.