Abstract

Abstract The determination of chlorophenoxyacetic acid herbicide residues was done with GC-ECD as pentafluorobenzyl derivatives. The herbicides were separated on a 3% Silar 10 CP column, which permits better resolution from interfering organic acids of environmental origin. The fortification study provides an 84–91% recovery for the water and sediment samples. The detection limits were established as 0.1 μg/1 for the water and 1.0–1.5 ng/g for the sediment samples. The use of a 3%Silar 10 CP packed column in the monitoring study as compared with a 1.5% OV-17 + 1.95% QF-1 one, shows the very small amount of contamination of the samples with these herbicide classes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.