Abstract

To report the use of a sterile, γ-irradiated corneal tissue without viable endothelium (VisionGraft Sterile Cornea; Tissue Banks International) in lieu of fresh donor cornea in Boston type 1 keratoprosthesis (KPro) implantation. Retrospective, interventional small case series. Eleven eyes of 11 patients underwent Boston type 1 keratoprosthesis implantation using VisionGraft Sterile Cornea between April 2009 and October 2010. Precut donut-shaped corneal lenticules, using femtosecond laser, measuring 8.5 mm in diameter with a 3-mm central hole were used. Surgical procedures were uneventful. Complete corneal re-epithelization was noted within 10 days in all cases. No complications related to the donor cornea (eg, stromal necrosis, wound leak, or device extrusion) occurred over an average follow-up of 16.5 months. VisionGraft Sterile Cornea eliminates the need for use of fresh donor corneal tissue for Boston type 1 keratoprosthesis procedures, which makes this procedure a viable sight-restoring option when donor corneal tissues are not readily available.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.