Abstract

The purpose of this study was to explore the use of miniplates as skeletal anchorages for orthodontic treatment and to investigate the stability of miniplates and the causes of failure. Forty-four miniplates were applied in the maxilla or mandible as skeletal anchorages in orthodontic treatment. Two weeks later, a force of 100 to 200 g was applied by an elastometric chain or nickel-titanium coil spring to move the teeth. To compare nominal variables related to miniplate failure, the chi-square or Fisher's exact test was used. The average insertion time of a miniplate was approximately 25 to 30 minutes. One miniplate loosened before orthodontic force loading. The other miniplate was removed after orthodontic force loading. The overall success rate was 95.5 percent. The authors found no significant differences in the risk factors for failure of miniplates. Miniplates are easy to insert for skeletal anchorage, simplify treatment mechanics, and shorten the orthodontic treatment period.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.