Abstract
This paper describes a new technique to suture the radioactive plaque to sclera. The radioactive plaque is conventionally sutured to the sclera using 5/0 nylon sutures. The imbricated suture technique involves using a 1/0 silk or 2/0 mersilene suture imbricated with the 5/0 nylon suture when the nylon suture is tied and cut. The imbricated suture technique allows easy identification of the plaque at removal and provides a surface that separates the 5/0 nylon from the surface of the eyelet platform, making suture cutting easier and safer. The radiation exposure times ranged from 9.1 minutes to 14 minutes (mean: 10.8 minutes) during plaque insertion and from 2.8 to 3.3 minutes (mean: 3.0 minutes) during plaque removal with the imbricated suture technique. This technique may decrease radiation exposure time and may prevent inadvertent scleral damage.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.