The concept and technique of using high-density porous polyethylene (HDPP), a nonresorbable synthetic material, for nasal spreader grafts, are presented. This material is thought to be particularly useful in revision (secondary or tertiary) rhinoplasty, in which internal valve collapse frequently is confronted and septal cartilage often is unavailable because it has been harvested for spreader or other grafts. Sold as a thin plain sheet (0.85 x 38 x 50 mm) that can be cut to an appropriate size for spreader grafts, HDPP is a ready-to-use material commercially available on the market. Because HDPP permits ingrowths of fibrous tissue inside and around, it is a nonabsorbable material that stabilizes the upper lateral cartilages in their new position and maintains the appropriate internal valve angle. The authors used this material for 15 patients undergoing secondary (n = 12) and tertiary (n = 3) rhinoplasty because of valvular collapse. During the mean follow-up period of 16 months (range, 8-30 months), neither complication nor recurrence of airway obstruction occurred.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.