Abstract

The use of transtympanic electrocoehleography (ECochG) is discussed in the diagnosis of endolymphatic hydrops. The electrophysiological concepts which may explain the finding of an increased negative summating potential (SP) in human recordings are discussed. The click SP/AP ratio and the absolute values of the 1 kHz 90 dB NHL tone burst were obtained in 42 normal ears, 48 sensory ears and 80 Meniere's ears and compared. It was found that the use of a 1 kHz tone burst increased the accuracy of diagnosis especially in ears with a hearing loss of less than 40 dB NHL from a false negative level of 54% (click SP/AL) to 23% (1 kHz tone burst SP). It was concluded that the 1 kHz tone bursts improved the accuracy of transtympanic electrocoehleography in the diagnosis of Meniere's disease.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.