The aim of the study is to assess the practical significance of the use of the digital marking device «VERION™ Image Guided System» in the technology of intrastromal keratoplasty using a femtosecond laser. Material and methods. According to the developed method, 35 eyes of 27 patients with a diagnosis of keratoconus of the 2nd degree were operated. The median age was 26 years. Formation of intrastromal tunnels was performed using «Femto LDV Z8» femtosecond laser («Ziemer», Switzerland), the laser was centered in strict accordance with the markings obtained by the digital marking device «VERION™ Image Guided System» («Alcon», USA). During the implantation of the segment, this device was also used for its precise positioning in the tunnel. Setting the projection of the required axis, the surgeon intraoperatively to visualize the label that corresponds to the exact position of the end of the segment in the intrastromal tunnel, and carried out precise positioning of the intrastromal segments. R esults. When performing operations using the indicated method, it was revealed that the patient’s eye at the aplanation stage of a femtosecond laser has a tendency to rotate and decentralize. Minor decentralizations relative to the pupil center were corrected by the displacement of the intrastromal tunnel pattern in the laser working program along the x-axis by 0.1 ± 0.05 mm, along the y-axis by 0.1 ± 0.04 mm. In patients in the postoperative period there was an increase in uncorrected and corrected visual acuity. By 3 months after the operation, functional parameters and keratometric data stabilized: visual acuity without correction and with maximum correction increased to 0.5 ± 0.16 and 0.7 ± 0.12, respectively, keratometry of flat and steep axis declined to 44.3 ± 1.4 and 50,8 ± 3,2 diopters, respectively. Conclusions. It was found that the applanation of the femtosecond laser aperture on the surface of the conical cornea leads to the rotation of the eye by an average of 9°. The use of femtosecond laser for forming the intrastromal tunnels in the conduct intrastromal keratoplasty requires mandatory marking of the cornea meridian the corresponding to the axis of the cutout for laser centration. Methodology of Verion-assisted femtosecond laser intrastromal keratoplasty allows to position the segments with high precision in accordance with a preoperative calculation that provides high clinical and functional results.

Highlights

  • Интрастромальная кератопластика как метод лечения кератоконуса применяется с 1996 г

  • Использование зоны «входа» в интрастромальный тоннель как ориентира при позиционировании сегментов в данном случае приведет к ошибочному топографическому положению сегментов в толще роговицы

  • Methodology of Verion-assisted femtosecond laser intrastromal keratoplasty allows to position the segments with high precision in accordance with a preoperative calculation that provides high clinical and functional results

Read more

Summary

МАТЕРИАЛ И МЕТОДЫ

По разработанной методике прооперировано 35 глаз 27 пациентов с диагнозом «кератоконус 2-й степени». 1. Маркировка роговицы по проекционной метке по оси 50° (ось вреза) помощи устройства «VERIONTM Image Guided System», по которой должен быть выполнен «вход» в интрастромальный тоннель. Сущность предлагаемой методики заключается в использовании системы «VERIONTM Image Guided System» для интраоперационного проецирования метки по заданной оси и градуированной разметки окружности роговицы, что позволяет с прецизионной точностью позиционировать интрастромальный сегмент согласно предоперационному расчету. Использование данной системы позволяет расположить вход в тоннель в произвольной зоне, при имплантации одного сегмента или двух асимметричных сегментов на удалении 25–30° от проксимального конца интрастромального сегмента и не использовать место вреза как ориентир при позиционировании сегмента в интрастромальном тоннеле. Расположение входа в интрастромальный тоннель вне сильной оси при имплантации одного или двух сегментов разной длины дуги на равном удалении от краев имплантата позволяет избежать риска протрузии при миграции сегмента внутри тоннеля [6]. Апланация апертуры фемтосекундного лазера на поверхность конической роговицы приводит к ротации глаза в среднем на 9°

До операции
СПИСОК ЛИТЕРАТУРЫ
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call