Abstract

The following case report describes using carbon dioxide (CO2) as contrast media for intravascular optical coherence tomography (OCT) imaging in the superficial femoral artery. For initial OCT imaging, 20 mL of iodinated contrast was used during automated pullback. This was followed by 20 mL of hand-injected dextran 40 in normal saline, and finally hand-injected 50 mL of CO2. CO2 gave comparable erythrocyte clearance and imaging quality compared with dextran and iodinated contrast. To our knowledge, this is the first reported case using both dextran and CO2 with OCT imaging of the superficial femoral artery. Using CO2 is a viable option in patients with contraindications to contrast or dextran use.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.