Abstract

Autogenous vein grafts are currently the number one choice in microsurgical practice for managing vessel length discrepancies. A significant percentage of these grafts is used in the venous system. Allografts may serve as a viable alternative source of vein grafts. Few studies in the past have described the use of cryopreserved vein grafts (1 mm in diameter) in the venous system. In the present study, we cryopreserved the femoral veins of rats and transplanted these across rat species (ACI to Lewis) as interpositional vein grafts into a defect in the femoral vein. Short-term patencies (21 days), expressions of systemic antigenicity, histology, and scanning electron microscopic studies were performed. We obtained 100% patencies with fresh control veins and cryopreserved veins at 21 days.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.