To determine the efficacy and safety of iliac branch device (IBD) implantation and to evaluate its limitations based on 7 years of experience in a single center. This single-center study included patients with bilateral common iliac artery aneurysms (CIAAs). We investigated follow-up CT and reviewed the internal iliac artery (IIA) patency and complications related to IBD. A retrospective analysis was performed and the overall survival rate and freedom from reintervention rate were reported according to the Kaplan-Meier method. Of the 38 patients with CIAAs, only 10 (12 CIAAs) were suitable for IBD treatment. Five patients underwent unilateral IBD insertion with contralateral IIA embolization, and three (60%) showed claudication; however, symptoms resolved within 6 months. The 7-year freedom from IBD-related reintervention rate was 77.8%. No procedure-related deaths occurred. IBD has good technical success and long-term patency rates; however, anatomical factors frequently limit its application, particularly in Asians. Additionally, unilateral IIA embolization showed relatively mild complications and a good prognosis; therefore, it can be performed safely for anatomically complex aortoiliac aneurysms.