Abstract

We report the effectiveness of an antegrade continence enema stopper device in preventing stomal stenosis in catheterizable channels. All cases in which a channel was created for clean intermittent catheterization during a 5-year period beginning in May 2002 were included in the analysis. For the first 31 months the catheterizable channels were used for clean intermittent catheterization but were not kept patent between catheterizations (group 1, 19 patients). For the next 29 months we began to use an antegrade continence enema stopper in the stoma between catheterizations for a period of 3 to 6 months postoperatively (group 2, 14 patients). A total of 33 catheterizable channels were studied. Six catheterizable channels in group 1 (32%) had to be revised within 6 months of reconstruction. No catheterizable channel in group 2 had to be revised. This difference is statistically significant (p = 0.02). An antegrade continence enema stopper inserted into the catheterizable channel for 3 to 6 months postoperatively effectively eliminates the incidence of stomal stenosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.