Abstract

BackgroundThe NiTi CAR™ 27 is a newer device that uses compression to create an anastomosis. An analysis of this device in the creation of colorectal anastomoses in humans has yet to be reported in the USA. MethodsA non-randomized, prospective pilot study of the NiTi CAR™ 27 device in patients undergoing a left-sided colectomy between March 2008 and August 2009 was performed. ResultsTwenty-three patients (9 men and 14 women) underwent a left-sided colectomy and compression anastomosis with the CAR™ 27 device. Minor morbidities, 3 of 23 (13%) patients, included one small postoperative abscess requiring antibiotics alone and two postoperative anastomotic strictures requiring balloon dilation. Major morbidities, 1 of 23 (4%) patients, included a partial anastomotic dehiscence/leak requiring surgical dismantling of the anastomosis and diversion. ConclusionThe CAR™ 27 device shows promise as a safe and effective alternative for the creation of colorectal anastomoses. However, studies in a larger patient population are warranted to demonstrate equivalence of this device.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.