Abstract

This paper deals with the collapse load of corroded parallel steel units, such as sets of corroded strands alone, or embedded in a concrete core. It is shown that what is relevant is the distribution of the damage between the units, and not the total area loss due to corrosion. The paper also shows that assuming that the area loss is related to the limit load loss is misleading, and potentially dangerous.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.