Abstract

The authors of this paper studied on the tracer gas method which had already been suggested for application in measuring the trapping efficiency of two stroke cycle engines. And in consequence, the superiority in both accuracy and reproducibility of measurement under the following conditions was recognized : The use of anhydrous monomethylamine as the tracer gas ; gas concentration being 0.1 to 0.3% ; the use of 10 cc of 0.02 normal solution of sulfuric acid as the absorbing liquid ; a mixture of bromcresol-green and methyl-red as the neutralization reagent. The type of sampling tube, the gas sampling points and the gas sampling apparatus are also selected. The accuracy are compared with the results obtained by the gas sampling valve method. Under these conditions, the errors are within the range of ±2%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.