Abstract

The study aims to use the fixed box model to calculate the spread of pollutants (CO2, SO2, NOX, particulate) resulting from the burning of fuel used to produce electrical energy in the Nasiriyah city and to know the way they spread in the city through being affected by the wind speed and compare the results calculated from the model with the results measured by the lancom4 device. The results showed that the main pollutants for the air in Nasiriyah was emitted from burning the fuel used for the production of electric power, and the results showed that the concentration of pollutants (CO2, SO2, NOX) was much higher inside the city when compared with the upstream direction of the winds due to its increase with the movement of winds and its entry into the city. Through the application of the fixed box model and when comparing the calculated results through the model with the results measured by the lancom4 device, the error rate was (4 %, 2%, 2%, 5%) for pollutants (CO2, SO2, NOX, particulate) respectively, it was also observed that the highest emission rate of pollutants was result from using heavy fuel (fuel oil) and the lowest emission was from light oil (Dry gas). We noted the spread of pollutants and dilution in the atmosphere increases with the increase in wind speed, excluding for particles mater.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call