Abstract

Water maintains a pH value of 7 owing to a balance between dissociation into hydronium (H 3 O + ) and hydroxide (OH − ) ions and their recombination. An examination is made of the effect of applying voltages from 0.1 to 0.82 V on these ions between metal electrodes which act as blocking electrodes. The movement of hydronium ions away from and hydroxide ions towards the anode is followed. This movement results in the formation of an ion double-layer with a steeply rising electric field and a maximum pH of approximately 12. At the cathode, the opposite occurs and the pH reaches a minimum of approximately 1.7. The time constant for double-layer formation is found to increase exponentially with voltage, and the pH at each electrode varies linearly with voltage; thus, the pH can be controlled systematically at each electrode. The dimensions of the double-layers are such that large biomolecules at the electrodes will be immersed in a pH environment close to the extreme values at the electrode. This means that the charge on the molecules may be controlled as they adsorb onto the electrode; this may prove valuable for the operation of biosensors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.