New phenomena discovered in the experimental research of the ultra-high frequency pulse tube cryocooler were presented. The cause of the new phenomena was analyzed and the third type DC flow was discovered in the pulse tube cryocooler. The third type DC flow not only deteriorated cooling capacity but also led to temperature instability of the pulse tube cryocooler. From the fluid network theory and the simple regenerator model, the root of the third type DC flow was concisely investigated in theory. The asymmetric resistance of oscillating flow in pulse tube cryocooler was the key mechanism of the third type DC flow. Some suppression methods were briefly discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.