Abstract

An experimental investigation of microstructural evolution has been conducted on Fe–15Cr–16Ni irradiated with 4.0 MeV nickel ions. Irradiations proceeded to dose levels ranging from ∼0.2 to ∼17 dpa at temperatures of 300, 400, 500 and 600 °C at dpa rates of 1 × 10 −4, 4 × 10 −4 and 1 × 10 −3 dpa/s. The swelling was found to monotonically increase with decreases in dpa rate at every irradiation condition studied. The earliest and most sensitive component of microstructure to both temperature and especially dpa rate was found to be the Frank loops. The second most sensitive component was found to be the void microstructure, which co-evolves with the loop and dislocation microstructure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.