AbstractThe oxygen glow discharge plasma modification of a contact lens material has been studied using SSIMS. SSIMS provides evidence at the molecular level for the conversion of surface organosiloxane species to inorganic silica functionalities with treatment time. These findings shown an excellent correlation with a dramatic increase in surface hydrophilicity, as derived from surface energy studies, on plasma treatment. This study further illustrates the potenial of SSIMS in the determination of the molecular changes at the surface during the plasma treatment process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.