Abstract

UV-sensitive products which undergo a colour change on exposure to UV radiation are available for use by the general public. We have evaluated SunCheck patches of various sensitivities, and Tanscan UV sensor cards, in terms of their temperature stability, wavelength response and response to sunlight. The products exhibited no perceptible colour change when the temperature was maintained at 45 degrees C for 4 hours; on exposure to monochromatic radiation, the sensitivity peaked at a wavelength of 335 and 355 nm for SunCheck and Tanscan, respectively; the response to sunlight under clear conditions was reasonably consistent, with the coefficient of variation for each type of material ranging between 12.5 and 27%. These products are based on the incorrect concept that there is a 'safe' dose of UV radiation. Thus, they cannot be recommended to the public as a reliable way of reducing the risk of skin cancer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.